5100mz-Plus Vibratome
 

5100mz-Plus Vibratome

Model 5100mz-Plus


  • Includes the Z-axis calibration unit (5100mz-Plus only)
  • Vibration frequency from 50 to 80 Hz
  • Adjustable amplitude from 0.5mm to 1.5mm
  • Fine control of the blade advance (min. 0.1 mm/sec)
  • Set start and finish position of blade travel
  • Remote controls allowing for sterile use in culture hood
  • Ice water bath easily removed for cleaning
  • Optional cold light and magnifier for clear observation
  • Optional Peltier cooled bath
  • Download Brochure
  • Download Full Bibliography
 

Details

The 5100-Plus is perfect for those who need to keep slices viable for longer e.g. for electrophysiological field recordings. The user can calibrate the Z-axis deflection of the blade to 2 µm with the adjustable blade holder and “Opti-cal” Calibration device. Minimal Z-axis deflection reduces the “chatter” and minimises damage to the slice surface, leading to greater viability of the cells on the slice surface.

The New 5100mz series Vibrating Microtome shares the User interface with the premium 7000smz-2, placing a wide range of adjustable parameters at the user’s fingertips:

  • Vibration frequency from 50 to 80 Hz
  • Adjustable amplitude from 0.5mm to 1.5mm
  • Fine control of the blade advance (min. 0.1 mm/sec)
  • Set start and stop position of blade travel
  • Control box on umbilical cord ideal for operation in an isolated environment

Use in fully manual or the semi-automated "Slice window" mode which automatically remembers the start and finish position of the slice.

Specifications

  • Section thickness step size: 0.001 mm
  • Bath table rise & fall speed: 1.0 mm/sec maximum
  • Maximum (vertical) travel of bath table: 19 mm
  • Cutting head advance speed:
    • Minimum: -2.0 mm/sec (-1.00 during slicing)
    • Maximum: +2.0 mm/sec (+1.00 during slicing)
  • Cutting head retraction speed: 2.0 mm/sec
  • Maximum travel of cutting head: 40 mm
  • Blade oscillation frequency
    • Minimum: 50 Hz
    • Maximum: 80 Hz (amplitude dependent)
  • Frequency step size: 5 Hz
  • Blade oscillation amplitude
    • Minimum: 0.5 mm (nominal)
    • Maximum: 1.5 mm (nominal)
  • Amplitude step size: 0.5 mm (nominal)
  • Power requirements (Selectable): 115VAC 60Hz, 230VAC 50Hz
  • Power rating: 100W
  • Fuse rating
    • 115V: T2A 250VAC
    • 230V: T2A 250VAC
  • Light source: Powered from 5100mz
  • Dimensions: 350mm Width x 450mm Depth x 350mm Height (excluding magnifier/light source)
  • Weight: 15kg (excluding magnifier)

Accessories

Required Accessories

Ceramic Blades - 5 pack
Ceramic Blades - 5 pack
Model 7550-1-C

Specialized Ceramic blades for Campden Vibrating Microtomes. These blades are honed with a single bevel for superior slicing.

Stainless Steel Blades - 50 pack
Stainless Steel Blades - 50 pack
Model 7550-1-SS

Specialized Blade Technology for Campden Vibrating Microtomes.

Optional Accessories

Bath Mount for Vibrating Microtomes
Bath Mount for Vibrating Microtomes
Model 7000-3-1A

Newly redesigned Bath Mount. Edge of the ice bath outer now has a rolled edge. Preventing vibration of the bath wall at certain harmonics of speed and amplitude, hence more stable, less splash, less evident vibration. Shown with standard and adjustable tissue mounts that can be ordered separately.

Temperature Controlled Standard Tissue Bath
Temperature Controlled Standard Tissue Bath
Model 7610A

Temperature controlled cooling baths for the 7000smz-2, 5000mz-2, 5100-Plus and 5100mz vibrotomes with a controllable temperature range of approx +10ºC to 0ºC with accuracy of ± 1 ºC. For experiments where exact control of a low slicing temperature is required.

Rectangular Tissue Mount
Rectangular Tissue Mount
Model 7000-4-3A

Rectangular specimen mount for dual specimen

Integrally Mounted Cold Light Source and Magnifying Glass
Integrally Mounted Cold Light Source and Magnifying Glass
Model 5100-1-3

A magnifying glass for general global slices offering approximately 1.5x magnification. Integral cold light powered directly via the Model 5100mz Vibrating Microtome.

Related Products

Dual channel PTFE chamber system for Electrophysiology with heater & thermistor feedback control
Dual channel PTFE chamber system for Electrophysiology with heater & thermistor feedback control
Model CI.7450-2P(E)

The new all-in-one chamber design incorporates the best features of both the old Haas or interface type cell and the old Oslo or submerged type cell.

Dual channel Acrylic chamber system for Electrophysiology with heater & thermistor feedback control
Dual channel Acrylic chamber system for Electrophysiology with heater & thermistor feedback control
Model CI.7450-2A(E)

The new all-in-one chamber design incorporates the best features of both the old Haas or interface type cell and the old Oslo or submerged type cell.

Quad channel Acrylic chamber system for Electrophysiology with heater & thermistor feedback control
Quad channel Acrylic chamber system for Electrophysiology with heater & thermistor feedback control
Model CI.7450-4A(E)

The new all-in-one chamber design incorporates the best features of both the old Haas or interface type cell and the old Oslo or submerged type cell.

Hex channel PTFE chamber system for Biochemistry with heater & thermistor feedback control
Hex channel PTFE chamber system for Biochemistry with heater & thermistor feedback control
Model CI.7450-6P(B)

The new all-in-one chamber design incorporates the best features of both the old Haas or interface type cell and the old Oslo or submerged type cell.

Hex channel Acrylic chamber system for Biochemistry with heater & thermistor feedback control
Hex channel Acrylic chamber system for Biochemistry with heater & thermistor feedback control
Model CI.7450-6A(B)

The new all-in-one chamber design incorporates the best features of both the old Haas or interface type cell and the old Oslo or submerged type cell.

Quad channel PTFE chamber system for Electrophysiolgy with heater & thermistor feedback control
Quad channel PTFE chamber system for Electrophysiolgy with heater & thermistor feedback control
Model CI.7450-4P(E)

The new all-in-one chamber design incorporates the best features of both the old Haas or interface type cell and the old Oslo or submerged type cell.

Copyright © 2024 Campden Instruments. All Rights Reserved.