Model STIM/PlexStim

PlexStim Electrical Stimulator System
 
   
 

DETAILS

PlexStim can generate arbitrary waveform patterns initiated from either the software interface or from externally triggered digital inputs with an unprecedented 30nA resolution and 1µsec temporal resolution. The specially designed Graphical User Interface (GUI) makes it easy to generate bi-phasic rectangular pulses and bursts of pulses repeated at specific rates. More complicated rectangular waveforms and non-rectangular arbitrary waveforms may be defined in and loaded from a simple text file.

Every stimulation pattern can be started and stopped either manually within the GUI, or with an external digital trigger (TTL). The Plexon Stimulator allows you to trigger each of the 16 analog output channels independently. Complex stimulation patterns can be delivered in this way with precise timing based on different triggers. Each channel has a dedicated digital input that may be used in an edge triggered or level triggered (gated) mode to initiate stimulation with microsecond latency. Each channel also has a dedicated digital output signal to other devices at the precise time when stimulation is occurring.

PlexStim delivers arbitrary stimulation waveforms in which the waveform current values are first defined within a text file and then downloaded to PlexStim via the software interface. In this way, biological signals recorded by data acquisition systems or curves derived from mathematical functions can be used as stimulation waveforms. Stimulation pulses can be repeated to generate pulse trains with arbitrary intra- and inter-burst intervals. Different waveform patterns and protocols can be applied to each of the 16 stimulation outputs. Stimulation protocols can be repeated and then stopped either manually or on a trigger event.

The actual current and voltage delivered to each electrode can be conveniently monitored on a per-channel basis with stimulation currents defined with 16-bit precision up to ±1mA and delivered with ±10V compliance.

PlexStim can be purchased independently or operated in conjunction with the OmniPlex® D Neural Data Acquisition System, the Multichannel Acquisition Processor (MAP) Data Acquisition System or the CinePlex® Behavioral Research System.

SPECIFICATIONS

Features

Specifications and Options

Electrically isolated

Yes

Devices used simultaneously

Up to 4 devices

Stimulation out connector

26 pin Harwin, Male

Digital out connector

20 pin Harwin, Male

Digital in connector

20 pin Harwin, Male

Voltage monitor channel output

BNC

Current monitor channel output

BNC

Stimulation cable – version 1

26 pin Harwin, Female to 20 pin Omnetics .050, Female

SDK availability

C/C++ and MATLAB®

Platform

Windows® 7

Computer interface

USB 2.0

Analog Outputs

Specifications and Options

Stimulation mode

Constant current

Number of analog output channels

16 outputs, 1 return

Maximum current

± 1mA

Resolution

16 bits

Output current resolution

30nA

Compliance voltage

10V @ 700µA

Temporal resolution

1µsec

Output rise time

1.25µsec (100µA, 10kÙ load)

Minimum pulse width

5µsec

Minimum pulse rate

100kHz

Digital Inputs/Outputs

Specifications and Options

Number of digital inputs

16

Number of digital outputs

17

Digital input levels

TTL, Low < 0.8V, High > 2.0V

Digital output levels

HCT, Low < 0.33V, High > 3.84V

Digital input/output latency

< 1µsec

Maximum trigger rate

100kHz

Minimum trigger pulse width

1µsec

Arbitrary Waveforms

Specifications and Options

Maximum sample points

1000

Maximum update rates

1MHz (1µsec)

Maximum waveform repetition

32,767

CONTACT US

Campden Instruments LTD
P.O. Box 8148
Loughborough, Leics.,
LE12 7XT. England

Tel: +44 1509 814790

uksales@campdeninstruments.com

NEXT EVENT

SfN 2017
Date: November 11 - 16, 2017
Location: Washington, DC

View All Upcoming Events

Home | Products | Support | About | Sitemap | Privacy

Copyright © 2009 - 2017 Campden Instruments LTD. All Rights Reserved.

PRODUCT SEARCH

Use the provided form to search for products on this website.

LOGIN

Please Login below or Register for a Lafayette Instrument Online Account.

 

 

 


CONTACT US

Campden Instruments LTD
P.O. Box 8148
Loughborough, Leics.,
LE12 7XT. England

Tel: +44 1509 814790

uksales@campdeninstruments.com

Copyright © 2009 - 2017 Campden Instruments LTD. All Rights Reserved.